BETTER HOME PRODUCTS SOMA V COLLECTION SPECIFICATIONS ITEM# 20110B - Passage Set
Grade III tubular passage set. All metal components Door Prep - Crossbore 2 1/8", Edge Bore 1", Latch Face 1"x2 1/4" Door Thickness - 1 3/8" to 1 3/4" Function: Both levers always free Strike - Full lip radius corner standard. Other options available Latch - 1/2" throw bolt, 2 3/8" or 2 3/4" backset adjustable. Radius corner face plate standard. Other options available Door Handing - Non - handed ITEM# 20210B - Privacy Set
Grade III tubular privacy set. All metal components Door Prep - Crossbore 2 1/8", Edge Bore 1", Latch Face 1"x2 1/4" Door Thickness - 1 3/8" to 1 3/4" Function - Both sides lever locked or unlocked by center turn- button inside. Also can be opened by emergency key out side Strike - Full lip radius corner standard. Other options available Latch - 1/2" throw bolt, 2 3/8" or 2 3/4" backset adjustable. Radius corner face plate standard. Other options available Door Handing - Non - handed ITEM# 20310B - Dummy Lever
Grade III dummy lever. All metal components Door Prep - Surface mounted with 2 exposed mounting screws. No door prep needed Door Thickness - greater than 1" Function: Active lever, for doors where only a pull / push is required. Door Handing - Non - handed ITEM# 25510B - Entry Set
Grade III tubular Lever-Lever entry set. All metal components Door Prep - Crossbore 2 1/8", Edge Bore 1", Latch Face 1"x2 1/4" Door Thickness - 1 3/8" to 1 3/4" Function: Both sides locked or unlocked by key out side or center turn- button inside Cylinder - 5 pins, Kwikset® KW 1 keyway Strike - Full lip radius corner standard. Other options available Latch - 1/2" throw dead latch, 2 3/8" or 2 3/4" backset adjustable. Radius corner face plate standard. Other options available Door Handing - None - handed ITEM# 20910B - Trim Lever
Grade III handleset trim lever, works for all
BHP offering handlesets.
All metal components Door Prep - See BHP handleset door prep Door Thickness - 1 3/8" to 1 3/4" Function: Lever always free Door Handing - Non - handed
Malnutrition protéino-énergetique et avitaminoses Actualités 2009 Professeur Pierre Aubry. Mise à jour le 27/08/2009 1. Généralités 1.1. La malnutrition protéino-énergétique (MPE) se rencontre en pratique dans 2 circonstances : - la MPE aiguë, situation catastrophique qui nécessite en situation de crise une stratégie d’aide alimentaire internationale, - la MPE chronique,
Where are we going, where have we been? Since the 2012 Pipeline Report , results from phase II trials and advances in preclinical development have brought the pipeline for new TB vaccines into sharper focus, even as correlates of protective immunity against TB remain elusive. Nearly empty in 2000, the current pipeline includes 14 vaccine candidates in clinical trials and over 35 candidates in